Opening Hour

Mon - Fri, 8:00 - 9:00

WhatsApp

+8618037022596

Ultrasonic Flowmeters Thermocouples, Pressure Transducers, Flow …

+

Clampon ultrasonic flow meters come in either single or dualsensor versions. In the singlesensor version, the transmit and receive crystals are potted into the same sensor body, which is clamped onto a single point of the pipe surface. A coupling compound is used ultrasonically connect the sensor to the pipe. In the dual sensor version, the transmit crystal is in one …

Flow Measurement | Flowmeter | Supplier | ABB

+

Flow Measurement With ABB''s knowledge about flow measurement and management, you have access to over 100 years of flow measurement and control experience to help you save cost and increase profits. Industrial Flow Measurement . Click here to download the comprehensive 290page handbook now. Product selection assistant. Comprehensive tool for selecting the most …

Differential Pressure Flow Elements DP Primary Elements ABB

+

The simple design of ABB Wedge Flow Elements with their Vshaped flow restriction makes them extremely robust and, when coupled with ABB’s leading range of electronic pressure transmitters, extremely accurate. The ABB Wedge flowmeter is bidirectional and is particularly suitable for fluids with high solid content, erosive/abrasive fluids and high viscosity fluids. The …

Flow measurement, flow control and flow sensors from Kobold

+

Air velocity sensor KAH. Mass Flow Meter Thermal MAS. Digital Mass Flow Meter and Regulator DMS. Mass Flow Meter Thermal KMT. Modular, Compact Inline Flow Meter KME. Mass Flow Meter Thermal KES1/3/4. Thermal Energy Flow Meter KEC . DualTube Coriolis Mass Flow Meter for LOW FLOW application HPC. Mass Flow Meter Coriolis TM/UMC3. …

ABB Instrumentation Torbar Averaging Pitot Tubes Economical Flow ...

+

ABB Instrumentation. 2 Torbar How TORBAR Works TORBAR produces an averaged differential pressure (DP) signal proportional to the square of the flow rate. The DP output is normally piped to a Differential Pressure transmitter in order to generate an electrical signal proportional to the flow rate. For certain applications, the DP transmitter can be directly mounted on to the …

TX and TS Thermal dispersion switches easurement made eas ABB

+

ABB RMA Form ..... 25 . Operating instruction manual | TX Thermal Disperson Level Switches 3 ... (air/vapor vs. liquid or high vs. low flows of air, vapor or liquid). Once the switch has stabilized in any given process condition, it can be adjusted such that a change (increase or decrease) in the amount of heat con ducted away from the heated RTD (thermal dispersion) due to a change in thermal …

Innovative solutions for accurate measurement and ... …

+

Process pressure Pressure class PN25, recommendation >1,5 Bar (>22 psi), no air Process pH 2,5 – 11,5 pH. Ambient temperature Sensor 20 to 60°C (4 to 140°F), display unit 10 to 60°C (14 to 140°F), Flow velocity No effect, Insertion type max flow 5m/s ( ft/s) Materials Sensor: SS 316L; Window: Ceramic, Display: Polycarbonate

Variable Area Flow Meter | Supplier | Manufacturer Flow ... ABB …

+

The V/A Master is a high accuracy variable area flowmeter suited with state of the art components and a wide angle visual flow indication. Glass tube flowmeter for optimum flexibility with a minimum number of components. The RatoSight is a variable area flowmeter specifically designed for marine, lubricant monitoring and seal water applications.

Technical information ABB Turbocharging Operating …

+

diffusor blades, in time forming a layer which reduces the compressor’s efficiency (Fig. 1). These particles have several origins. The air taken by the compressor via filter from the ship’s engine room is often mixed with oil vapours. Also, the engine room ventilation system sucks in air from outside, and this can be laden with dust, in ports where ores are handled. Another factor is the salt in sea air. What …

Baumer Passion for Sensors | Baumer India

+

The calorimetric flow sensor for the dairy industry solves many applications from process to packaging. FlexFlow for monitoring and ensuring the cleaning speed in the flow and return lines of your CIP system for optimum cleaning results throughout the system. O300 The new performance categories in optical sensor technology The new optical sensors are now available in two sizes: O500 followed by …

TX and TS Thermal dispersion switches easurement made eas ABB

+

ABB RMA Form ..... 25 . Operating instruction manual | TX Thermal Disperson Level Switches 3 ... (air/vapor vs. liquid or high vs. low flows of air, vapor or liquid). Once the switch has stabilized in any given process condition, it can be adjusted such that a change (increase or decrease) in the amount of heat con ducted away from the heated RTD (thermal dispersion) …

SwirlMaster FSS430, FSS450 Swirl flowmeter ABB

+

Sensor design Piezo sensor with two pairs of sensors for flow measurement and vibration compensation Approvals for explosion protection ATEX / IECEx, cFMus, NEPSI * Indication of accuracy in % of the measured value (% of ) 4 SWIRLMASTER FSS430, FSS450 SWIRL FLOWMETER | DS/FSS430/450 EN REV. F Overview models Transmitter Model …

Airflow Sensors | Honeywell

+

Airflow Sensors. Contain advanced microstructure technology to provide a sensitive fast response to flow, amount/direction of air or other gases. All airflow sensors operate on heat transfer — flow and differential pressure. Silicon chip design is created from thinfilm, thermally isolated bridge structure, containing both heater and ...

Stateoftheart gas turbines – a brief update

+

6 ABB Review 2/1997 in cooling air, however, carries with it the risk of an increase in NO x emissions, since the airmass flow in the lean premix combustor decreases. Advances in aeroengine technology are applied in full here to the areas of cooling, materials and computerbased fluid dynamics. The sequential combustion technology employed by ABB in the GT24 and GT26 gas turbines allows a …

Thermal Mass Flowmeter Sensyflow FMT700P ABB

+

To achieve the provided measuring accuracy, the sensor needs to be installed in the available ABB measuring sections. Figure 7: Standard measuring sections The use of an ABB measuring section with an uninterrupted inlet section of 10 × D* and an outlet section of 5 × D* in connection with an air filter or flow conditioner complies with

THE PRINCIPLES OF AIR FLOW, AIR PRESSURE, AND AIR …

+

The air flow through a conduit (ductwork) or a filter is expressed by the equation: Q = V × A Therefore, to find either of the other values, the equation can be rewritten as: V = Q ÷ A A = Q ÷ V An example of the application of this equation would be a 24in. × 24in. × 2in. flat panel filter (A = 4 ft2) placed in an airstream of 2000 cfm (Q = 2000 cfm). The velocity through the filter in this example would be 500 …

Thermal Mass Flowmeter | Mass Flow Measurements Thermal ... …

+

SensyMaster’s concept comprises high grade thermal sensor elements with superior longterm stability, the common ABB look and feel with ABB specific menu structures and throughtheglassoperation and the ABB platform based electronics with comprehensive signal evaluation capabilities for a high degree of performance and reliability. The software offers the …

Aalborg, Manufacturer of High Quality Flow Instrumentation

+

Aalborg Variable Area Flow Meters, Thermal Mass Flow Meters, Thermal Mass Flow Controllers, MultiParameter Mass Flow Controllers, Paddlewheel Meters, Pumps, Vortex Flow Meters, Valves, Accessories, Aalborg, flow meter, rotameters, mass flow meters, mass flow controllers, vortex, valves

Aichi Tokei Denki Co.,ltd.

+

Flow Sensor; NW / NWP Instantaneous Flowrate/ Integrating Flow Volume Flowmeter; NDV10 Smallsize Flowsensor; TRA Ultrasonic Flow Meter for Liquid; AGV Electromagnetic Flow Meters for Agricultural Applications; System; ATZTA TRX / ATZTA TRZ Ultrasonic Flow Meter For Compressed Air and Nitrogen; ATZTA TRX Ultrasonic Flow Meters For Compressed Air and …

THE PRINCIPLES OF AIR FLOW, AIR PRESSURE, AND AIR …

+

The air flow through a conduit (ductwork) or a filter is expressed by the equation: Q = V × A Therefore, to find either of the other values, the equation can be rewritten as: V = Q ÷ A A = Q ÷ V An example of the application of this equation would be a 24in. × 24in. × 2in. flat panel filter (A = 4 ft2) placed in an airstream of 2000 cfm (Q = 2000 cfm). The velocity through the filter in …

Digital Mass Flowmeter | Process Applications Thermal ... ABB …

+

Sensyflow FMT500IG is a digital mass flowmeter for air, gases and gas mixtures in process applications. Home ; Offerings ; Measurement Analytics ; Flow ; Thermal mass flowmeters ; Sensyflow FMT500IG; Global site . ABB''s website uses cookies. By staying here you are agreeing to our use of cookies. Learn more. I agree: Navigate; Search; Login; layouts …

Baumer Passion for Sensors | Baumer India

+

The calorimetric flow sensor for the dairy industry solves many applications from process to packaging. FlexFlow for monitoring and ensuring the cleaning speed in the flow and return lines of your CIP system for optimum cleaning results throughout the system. O300 The new performance categories in optical sensor technology The new optical sensors are now …

INSTRUCTION MANUAL KC/3 BLADE CONSISTENCY TRANSMITTER

+

such as: mechanical strikes to the blade sensor and process pressure shocks. There are no seals in contact with the process flow therefore leakage into the sensor unit is virtually impossible. KC/3 wiring connections and signals are described in figure KC/3 does not require regular maintenance and is simple to operate. There are no moving parts to wear out. Grade selection (3 binary inputs) Sample …

SwirlMaster FSS430, FSS450 Swirl flowmeter ABB

+

Sensor design Piezo sensor with two pairs of sensors for flow measurement and vibration compensation Approvals for explosion protection ATEX / IECEx, cFMus, NEPSI * Indication of accuracy in % of the measured value (% of ) 4 SWIRLMASTER FSS430, FSS450 SWIRL FLOWMETER | DS/FSS430/450 EN REV. F Overview models Transmitter Model number FSS430 / FSV430 …

Stateoftheart gas turbines – a brief update

+

6 ABB Review 2/1997 in cooling air, however, carries with it the risk of an increase in NO x emissions, since the airmass flow in the lean premix combustor decreases. Advances in aeroengine technology are applied in full here to the areas of cooling, materials and computerbased fluid dynamics. The sequential combustion technology employed by ABB in the GT24 and GT26 …

Thermal Mass Flowmeter | Air Measurement Thermal Mass ... …

+

The measuring section consists of inlet and outlet sections of the appropriate size and of an air filter or flow conditioner which can be connected – to an air duct – via the connection piece on the suction side. The Sensyflow FMT700P Compact can simultaneously operate one analog output (current 0 / 4 to 20 mA or voltage 0 to 5 / 10 V), one digital output (frequency, pulse, …

Leave a comment